Christer , Amanda , Sandra , Urban , Michael , and Per: Significant beat-to-beat variability of E/e’ irrespective of respiration.

Introduction

One of the main objectives of echocardiographic examinations is the assessment of intracardiac pressures. In particular, the ratio between early diastolic blood flow velocity and early diastolic myocardial velocity (E/e’) is often used to assess pulmonary capillary wedge pressure (PCWP) (Nagueh S page 2). Typically, a few cardiac cycles are recorded and the average reading is calculated. The cardiovascular system comprises several oscillating components, including physiological transients, respiration, loading conditions, heart rate variability, blood pressure variability, etc which may potentially influence the E and e’ velocities3. In particular, the influence of respiration on LV function has been shown to be related to age and heart disease4,5. Although standard echocardiography guidelines recommend acquiring images and Doppler recordings at end-expiration6, significant velocity variability might remain within the expiratory phase7. The aim of this pilot study was to assess the beat-to-beat variability of the E/e’ ratio within a minute of continuous recording in healthy young and old subjects, and patients with varying severity of amyloid heart disease.

Methods

Subjects

Seven subjects participated in this study: two young (20-30y), two middle aged (50-60y) healthy subjects, and three patients (65-72y). The patients had fat biopsy proven ATTR (amyloid transthyretin type) amyloid disease with increased septal wall thickness (>20 mm) who had clearly defined different patterns of

LV filling and diastolic dysfunction: type 1, abnormal relaxation (E/A < 1); type 2, pseudo-normalization (E/A >1<2); and type 3, restrictive (E/A >2) pattern. All subjects gave informed consent to participate in the study which conformed to the declaration of Helsinki and was approved by the Regional ethics committee of Umeå.

Echocardiographic examination

A 60 seconds long Doppler echocardiographic examination was acquired using a Vivid E9 ultrasound scanner with a M5S cardiac probe (GE Medical, Horten, Norway) in color Doppler imaging mode (CDI). Subjects were examined in the semi-left lateral position. The imaging sector depth, width and location were optimized for maximal frame rate, allowing simultaneous registration of septal axial myocardial motion (B-mode) and blood flow velocity (CDI) across the mitral annulus. A two-chamber view with 45 degrees field-of-view was used for the B-mode sequence, and a 10 deg field-of-view was used for the CDI sequence to cover the tip of the mitral valve. Respiration and ECG were simultaneously recorded by the ultrasound system. The frame rates of the CDI and B-mode image sequences were 100 Hz and 33 Hz, respectively. Image sequences were exported in hdf5 format for offline processing, with the CDI and B-modes as separate image sequences.

Simultaneous mitral (E) and septal myocardial (e’) velocities were measured for each heart beat by validated in house software8. Myocardial velocity curves were obtained by a speckle-tracking technique from a ROI at the proximal septum of the B-mode sequence, and mitral flow velocity curves was measured from the CDI sequence.

Table 1:

E/e’ beat-to-beat variability. Values in italics are coefficient of variation (CV).

Young 1 Young 2 Middle aged 1 Middle aged 2 Patient 1 (Relax) Patient 2 (Pseudo) Patient 3 (Restrict)
Without guideline procedure
Beat-tobeat 4,2 (4,0) 6,0 (6,0) 9,1 (10,4) 10,1 (12,0) 15,9 (12,8) 12,1 (7,5) 11,4 (3,7)
CV, % 48,1 50,5 57,0 58,2 40,3 31,0 16,2
Using guideline procedure
End expiration 4,9 (2,2) 6,4 (5,3) 10,2 (7,9) 10,5 (10,6) 16,3 (5,5) 12,0 (6,2) 11,4 (2,5)
Difference 1,4 (0,5) 0,8 (0,3) 2,3 (2,6) 0,8 (0,4) -0,35 (-0,6) -0,46 (0,41) -0,22 (-0,82)
CV (endexpiration), % 22,4 35,6 38,7 50,5 16,9 25,8 11,0

Variability in E/e’ was quantified separately on a beat-to-beat, end-inspiration, and end-expiration basis using the coefficient of variation (CV) calculated as range divided by mean.

Results

The Figure illustrates the beat-to-beat variability over one minute long acquisition for healthy subjects and patients. The results of the E/e’ variability of all subjects are summarised in the Table.

50-60 % in healthy subjects but to a significantly lesser extent in patients with heart failure. The least variability was in the patient with restrictive LV filling. Furthermore, such variability remained consistent during end-expiration, even when using standard guidelines for Doppler echocardiographic acquisition.

Although our findings are based on individuals rather than a cohort they seem to draw a pattern of interaction between cardiac function and intra-thoracic pressure changes. In young normals with compliant cardiovascular and respiratory systems even minor alterations in venous return result in significant beat to beat variability, a picture that is compromised in older people without cardiac disease. This highlights the effect of age on the systemic and pulmonary circulations as well as respiratory

Figure:

Beat-to-beat variability of E/e’. The phases of the respiration are indicated by (·) = end-expiration and (*) = end-inspiration.

icfj.2013.1.2.88-g001.jpg

Beat-to-beat variability was higher in healthy subjects compared to patients (50-60% vs 16-40%), and variability decreased according to disease severity (relaxation abnormality to restrictive). The respiratory phase was relatively coherent with the E/e’ signal in healthy subjects but not in patients. Mean and range of variability of E velocity was 7.2 (3.1), 5.0 (2.5) and 3.0 (1.0) %, for the young, old and patient groups and corresponding values of e’ were 20.2 (16.3), 15.7 (4.9), and 8.0 (3.2) %.

In healthy individuals E/e’ was higher at end-expiration compared to end-inspiration but there was no difference in the patients, irrespective of disease severity. Also, variability with expiration was higher in the healthy compared to patients (23-50% vs 11-26%).

Discussion

In this pilot study continuous and simultaneous recordings of LV filling and myocardial velocities varied between consecutive beats, resulting in significant E/e’ variability. The variation was

system. As for heart failure and progressive increase in left atrial pressure and intra-thoracic pressure, the normal variability drops to the minimum suggesting that the raised filling pressures take the upper hand in dictating the pattern of LV filling and myocardial lengthening. These findings propose that considering E/e’ as a simplified marker of raised left atrial pressure may only apply to patients with end stage heart failure rather than all comers with different disease severity and pathologies.

This study presents for the first time beat-to-beat information on simultaneously recorded myocardial and blood flow velocities. A potential limitation of this study is that the blood flow velocity was quantified using color Doppler mode, thus giving lower peak velocities as compared to pulsed wave Doppler therefore not comparable in absolute values. However, since the study assesses the variability in peak velocities, the normalized values of the CV should minimize this limitation.

References

1. 

Nagueh S E/e’: An index of LV filling pressures revisited. ICF Journal. 2013; 2: 2

2. 

Mullens W, Borowski AG, Curtin RJ, Thomas JD, Tang WH Tissue Doppler imaging in the estimation of intracardiac filling pressure in decompensated patients with advanced systolic heart failure. Circulation.. 2009; Jan 6119(1)62–70

3. 

Stefanovska A Coupled oscillations - complex but not complicated cardiovascular and brain interactions. IEEE Eng Med and Biol Mag,. 2007; 26: 25–29

4. 

Caiani EG, Turiel M, Muzzupappa S, Porta A, Baselli G, Pagani M, Cerutti S, Malliani A Evaluation of respiratory influences on left ventricular function parameters extracted from echocardiographic acoustic quantification, Physiol Meas,. 2000; 21: 175–186

5. 

Caiani EG, Turiel M, Muzzupappa S, Colombo LP, Porta A, Baseli G Noninvasive quantification of respiratory modulation on left ventricular size and stroke volume, Phyiol Meas,. 2002; 23: 567–580

6. 

Nagueh SF, Appleton CP, Gillebert TC, Marino PN, Oh JK, Smiseth OA, Waggoner AD, Flachskampf FA, Pellikka PA, Evangelisa A Recommendations for the evaluation of left ventricular diastolic function by echocardiography, Eur J Echocardio,. 2009; 10: 165–193

7. 

Albano A, Gustavsson S, Lindqvist P, Wiklund U, Grönlund C Echocardio-variability – Low and high frequency beat-to-beat variability in echocardiographic signals, Computing in Cardiology,. 40: 767–7702013; Zaragoza, Spain

8. 

Grönlund C, Claesson K, Dhooge J, Henein YM, Lindqvist P Simultaneous quantification of myocardial and blood flow velocities based on Duplex mode ultrasound imaging. J Biomed Eng Online,. 2013; 12: 107